Name

UF Water Purification System

Number
Affiliate classification
没有此类产品
Product description

Ultrafiltration principle

Ultrafiltration membrane screening process is driven by the pressure difference on both sides of the membrane. As the intermediary of system, ultrafiltration membrane is under certain pressure. When the original fluid flows through the membrane surface, ultrafiltration membrane surface with many tiny pores allow only water and small molecules go through and become the liquid, and the concentrate greater than the surface micro aperture is trapped in the liquid side of the membrane. Therefore the purpose of purification, separation and enrichment of concentrate can be achieved.

Specification:

Products series

HRP

HRR

HRD

Applied Range

Pre-treatment for industry water

Recycle of waste water and sewage

Treatment of drinking water

Model

P-

2640

P-

2660

P-

2680

R-

2680

R-

2880

D-

2660

D-

2860

D-

2880

Size

Housing Length

(mm)

1356

1856

2356

1860

2360

1856

1860

2360

Housing OD

(mm)

165

165

165

225

225

165

225

225

Membrane Area

(m2)

20

33

44

52

70

33

52

70

Parameter

Shape

hollow fiber

hollow fiber

hollow fiber

Materials

PVDF

PVDF

PVDF

Nominal Bore

(um)

0.03

0.03

0.03

OD of hollow fiber(mm)

1.3

1.3

1.3

Water Permeability(lmh)

50-120

40-100

60-120

PH

2-11

2-11

2-11

T()

1-40

1-40

1-40

Inlet pressure(bar)

6.0

6.0

6.0

NaClO Max concentration(ppm)

5000

5000

5000

Typical process condition

 

Max TMP(bar)

2.1

2.1

2.1

Max inlet TSS(ppm)

100

150

100

Typical inlet TSS(ppm)

50

50

50

Max OD of inlet granule(um)

300

300

300

Max inlet fiber impurity(ppm)

50

50

50

Typical inlet fiber impurity(ppm)

5

5

5

Max backwashing pressure(bar)

2.5

2.5

2.5

Backwashing flow(lmh)

100-200

100-200

100-200

Backwashing

 period

once every 15-60 min

once every 15-60 min

once every 15-60 min

Backwashing time(sec)

30-60

30-60

30-60

Typical chemical washing period

4-12 times annually

4-12 times annually

4-12 times annually

Air washing period

1-12times everyday

1-12times everyday

1-12times everyday

Corresponding parameter set not found, please add it in property template of background