ADD: No. 67 Guangrui west Road, Hedong District, Tianjin, China
TEL:86-022-84236524
FAX:86-022-84236637
Website:en.huakanintl.com
E-mail:[email protected]
Copyright © 2010 TIANJIN HUAKAN INTERNATIONAL TRADE CO., LTD. All Rights Reserved. 津ICP备06010489号 Powered by www.300.cn
1. Introduction:
HB series CLO2 generator is the patented product designed and produced by our own, using chemical method making ClO2 and CL mixed disinfection liquid by NaClO3 and HCL, application range includes kinds of drinking water.
2. Reaction Principle:
NaCLO3+2HCL→CLO2+1/2CL2+NaCL+H2O
Raw material: Sodium chlorate (GB/T1618-1995, content: more than 99%), Hydrochloric acid (GB320-93, concentration: more than 31%).
3. Features:
(1) For production of compound disinfectant (chlorine dioxide as main, chlorine gas as auxiliary), calculated by available chlorine, CLO2 : more than 75%.
(2) Flow-meter dosage system for transferring raw material ensures simple operation, accurate material input, un-blockage and stable performance.
(3) Main reaction pot adopts imported compound material that is temperature-resistant, anti-corrosion with long life time.
(4) Total convertible rate of raw material≥85%, low energy consumption.
(5) Semi-auto run of machine, no need of extra worker if there’s enough material.
(6) Upper-positioned material basket is suitable for low water pressure area.
3. Technical Parameters:
Model |
HB-50 |
HB-100 |
HB-200 |
HB-400 |
HB-500 |
HB-800 |
HB-1000 |
HB-2000 |
CLO2 |
50 |
100 |
200 |
400 |
500 |
800 |
1000 |
2000 |
NaCLO2 (%) |
10 |
10 |
10 |
10 |
10 |
23 |
23 |
23 |
NaCLO3 (%) |
30 |
30 |
30 |
30 |
30 |
30 |
30 |
30 |
HCL |
30 (10) |
30 (10) |
30 (10) |
30 (10) |
30 (10) |
30 |
30 |
30 |
Working Temperature |
5-40℃ |
|||||||
Inlet/outlet pipe size(mm) |
20 |
20 |
20 |
25 |
25 |
25 |
25 |
25 |
Inlet pressure of dilution water(Mpa) |
0.25-0.44 |
|||||||
Outlet pressure of disinfectant |
≤0.1 |
|||||||
Power consumption |
0.4 |
0.4 |
0.4 |
0.4 |
0.4 |
0.4 |
0.4 |
1.0 |
Build-up |
over-the-wall |
cabinet type |
||||||
Size |
600×300×900 |
600×300×900 |
600×300×900 |
700×500×1000 |
700×500×1000 |
700×500×1200 |
700×500×1500 |
900×700× 1500 |
Model |
HB-3000 |
HB-5000 |
HB-8000 |
HB-10000 |
HB-12000 |
HB-15000 |
HB-20000 |
CLO2 |
3000 |
5000 |
8000 |
10000 |
12000 |
15000 |
20000 |
NaCLO2 (%) |
23 |
23 |
23 |
23 |
23 |
23 |
23 |
NaCLO3 (%) |
30 |
30 |
30 |
30 |
30 |
30 |
30 |
HCL |
30 |
30 |
30 |
30 |
30 |
30 |
30 |
Working Temperature |
5-40℃ |
||||||
Inlet/outlet pipe size(mm) |
32 |
32 |
40 |
40 |
40 |
50 |
50 |
Inlet pressure of dilution water(Mpa) |
0.25-0.44 |
||||||
Outlet pressure of disinfectant |
≤0.1 |
||||||
Power consumption |
1.0 |
1.5 |
1.5 |
4.0 |
4.0 |
4.0 |
4.0 |
Build-up |
cabinet type |
||||||
Size |
900×700×1600 |
900×700×1800 |
900×700×1800 |
900×700×1800 |
1000×800×2000 |
1000×800×2000 |